Input voltage: DC 9-30 V
Ports: 3
Transmission distance: 1200 m
Baud rate: 1200-115200, auto-detected
Isolation: opto-isolation on every port
Port protection: ESD and lightning surge protection
Data format: data bits and parity auto-detected
Nodes: up to 256 per port
The LK-RS2102 2-port opto-isolated RS485 hub is a splitter that takes one RS485 input and provides two outputs, acting as both a signal splitter and a repeater. It solves the problems caused by irregular star wiring, adds communication ports and increases the number of slaves the bus can carry. Opto-isolation between the master and slave ports protects the master from interference, and the 15 kV ESD and 5 kA lightning surge protection devices shield the equipment from lightning and static damage. Data direction is detected in hardware, so the RS485 transmit/receive direction is switched with no delay. The power input is protected against overvoltage, overcurrent and reverse polarity, and the master and slave sides use isolated supplies. Each of the three ports has two activity LEDs, so the state of every port can be seen at a glance. Data passes transparently between master and slave ports with no restriction on baud rate, protocol or frame format - no configuration is needed, just plug and play.
Input voltage: DC 9-30 V
Ports: 3
Transmission distance: 1200 m
Baud rate: 300-115200, auto-detected
Isolation: full opto-isolation of signal and power
Port protection: 15 kV ESD, 5 kA surge
Nodes: up to 250
Applications: star wiring, signal branching, repeating
The LK-RS5102PS fully opto-isolates the master and slave ports while keeping transmission completely transparent. Data direction is detected in hardware, so one master port can be expanded into two slave branches with no configuration at all, and multiple layers of protection plus per-port activity LEDs keep the installation reliable on demanding sites.
Input voltage: DC 9-30 V
Ports: 5
Transmission distance: 1200 m
Baud rate: 1200-115200, auto-detected
Nodes: up to 256 per port
Isolation: opto-isolation on every port
Port protection: ESD and lightning surge protection
Data format: data bits and parity auto-detected
The LK-RS2104 4-port opto-isolated RS485 hub is a splitter that takes one RS485 input and provides four outputs, acting as both a signal splitter and a repeater. It solves the problems caused by irregular star wiring, adds communication ports and increases the number of slaves the bus can carry. Opto-isolation between the master and slave ports protects the master from interference, and the 15 kV ESD and 5 kA lightning surge protection devices shield the equipment from lightning and static damage. Data direction is detected in hardware, so the RS485 transmit/receive direction is switched with no delay. The power input is protected against overvoltage, overcurrent and reverse polarity, and the master and slave sides use isolated supplies. Each of the five ports has an activity LED, so the state of every port can be seen at a glance. Data passes transparently between master and slave ports with no restriction on baud rate, protocol or frame format - no configuration is needed, just plug and play.
Input voltage: DC 9-30 V
Ports: 5
Transmission distance: 1200 m
Baud rate: 300-115200, auto-detected
Nodes: up to 250 slaves per channel
Isolation: full opto-isolation of signal and power
Port protection: 15 kV ESD, 5 kA surge
Applications: multi-bus expansion, star networks
The LK-RS5104PS splits one RS485 input into four outputs. Every port has opto-isolated signal and power plus surge and ESD protection, so it can expand several branches reliably in automation and IoT installations while keeping the master device safe.
Input voltage: DC 9-30 V
Ports: 7
Transmission distance: 1200 m
Data format: data bits and parity auto-detected
Baud rate: 1200-115200, auto-detected
Nodes: up to 256 per port
Isolation: opto-isolation on every port
Port protection: ESD and lightning surge protection
The LK-RS2106 6-port opto-isolated RS485 hub is a splitter that takes one RS485 input and provides six outputs, acting as both a signal splitter and a repeater. It solves the problems caused by irregular star wiring, adds communication ports and increases the number of slaves the bus can carry. Opto-isolation between the master and slave ports protects the master from interference, and the 15 kV ESD and 5 kA lightning surge protection devices shield the equipment from lightning and static damage. Data direction is detected in hardware, so the RS485 transmit/receive direction is switched with no delay. The power input is protected against overvoltage, overcurrent and reverse polarity, and the master and slave sides use isolated supplies. Each of the seven ports has an activity LED, so the state of every port can be seen at a glance. Data passes transparently between master and slave ports with no restriction on baud rate, protocol or frame format - no configuration is needed, just plug and play.